Have any questions?       +86-13236009512   info@orthopro.mx

Femoral Intramedullary Nail System | Titanium Interlocking Nail for Femoral Shaft Fractures

The Femoral Intramedullary Nail is a comprehensive system designed to provide stable fixation for various femoral shaft fractures. This advanced Femoral Intramedullary Nail features versatile locking options and an anatomic bow to fit the natural curvature of the femur. Engineered for durability, our femur interlocking nail ensures superior rotational stability and promotes effective bone healing in trauma patients.

Standard of Care for Femoral Shaft Fractures

At OrthoPro, we are committed to advancing orthopedic trauma care through precision engineering. Our Femoral Intramedullary Nail system is a testament to this commitment, offering a robust and reliable solution for the fixation of femoral fractures. Intramedullary nailing has become the gold standard for treating femoral shaft fractures, and our system is designed to meet the diverse needs of surgeons and patients globally.

The Femoral Intramedullary Nail is developed to handle the high biomechanical stresses placed on the femur. Whether treating simple mid-shaft fractures or complex comminuted injuries, this system provides the rigidity required for stability while allowing for the micromotion necessary for secondary bone healing. As a trusted B2B partner, OrthoPro supplies these high-quality implants to hospitals and distributors worldwide, ensuring cost-effectiveness without compromising on clinical outcomes.

Key Features and Biomechanical Design

Our femur interlocking nail integrates several design features that facilitate surgical ease and postoperative stability:

  • Anatomic Geometry: The nail possesses a radius of curvature that matches the average anatomical bow of the femur (typically 1.5m to 2.0m radius), facilitating easier insertion and reducing the risk of jamming or cortical impingement.
  • Versatile Locking Options: The system allows for both static and dynamic locking. Static locking neutralizes rotational and axial forces, while dynamic locking allows for compression at the fracture site upon weight-bearing, which is crucial for fracture union.
  • Cannulated Structure: The hollow design enables insertion over a guide wire, supporting closed reduction techniques that preserve the fracture hematoma and soft tissue envelope.
  • Universal Design: Depending on the specific configuration, many of our nails can be used for either left or right femurs, simplifying inventory management for hospitals.
  • Material Excellence: Manufactured from biocompatible Titanium Alloy (Ti-6Al-4V) or Medical Grade Stainless Steel, offering an optimal balance of strength and elasticity closer to that of natural bone.

Indications for Use

The Femoral Intramedullary Nail is indicated for a wide variety of femoral disorders, making it a versatile tool in the operating room:

  • Fractures of the femoral shaft (Winquist-Hansen types I-IV).
  • Ipsilateral femoral neck/shaft fractures (when used with reconstruction locking).
  • Impending pathological fractures due to metastasis.
  • Malunions and non-unions of the femur.
  • Subtrochanteric fractures (specific indications apply).

Technical Specifications

We offer a comprehensive range of dimensions to accommodate different patient anatomies, from pediatric to large adult sizes.

Parameter Specification Details
Material Titanium Alloy / Stainless Steel
Nail Diameter 8mm, 9mm, 10mm, 11mm, 12mm, 13mm
Nail Length 320mm to 480mm (available in 20mm increments)
Proximal Diameter 13mm (Standard)
Locking Screws 4.5mm / 5.0mm Cortical Screws
Instrumentation Compatible with standard Cannulated Nailing Instrument Sets
End Caps Available in various lengths (0mm, 5mm, 10mm) to prevent bone ingrowth

Surgical Advantages

The implantation of the Femoral Intramedullary Nail is supported by a user-friendly instrumentation set. The system supports antegrade (from the hip) insertion points, such as the pyriform fossa or the tip of the greater trochanter.

Minimally Invasive Approach: The instrumentation is designed for small incisions, reducing blood loss and infection rates. The radiolucent targeting devices allow for precise distal locking screw placement with minimal radiation exposure to the surgical team.

Rotational Stability: The proximal and distal locking configurations are engineered to prevent rotation of the distal fragment, a common challenge in unstable femoral fractures.

Why Partner with OrthoPro?

In the global market for orthopedic implants, OrthoPro stands out by prioritizing quality, reliability, and service:

  1. Rigorous Quality Control: Our manufacturing facilities adhere to ISO and CE standards, ensuring that every intramedullary nail is defect-free.
  2. Inventory Solutions: We understand the urgency of trauma surgery. We maintain robust stock levels to ensure rapid shipping for distributors.
  3. Competitive B2B Pricing: Our direct supply chain model allows us to offer premium implants at prices that maximize your margin.
  4. Marketing Support: We provide high-resolution product images and technical manuals to help you succeed in your local market.

Choose the Femoral Intramedullary Nail from OrthoPro for a solution that combines clinical efficacy with economic value.

Contact Us for a Quote

Are you a distributor or hospital procurement manager looking for high-quality femoral nails? Contact our team today for a customized quote and shipping information.

Please visit our Contact Page or email us directly at info@orthopro.mx.