Have any questions?       +86-13236009512   info@orthopro.mx

Distal Femur Intramedullary Nail | Titanium Retrograde DFN System for Supracondylar Fractures

The Distal Femur Intramedullary Nail is a specialized retrograde system engineered for the stabilization of distal femur fractures, including supracondylar and intra-articular injuries. This advanced DFN system offers superior biomechanical stability through multi-planar locking options. Designed for trauma surgery, our Distal Femur Intramedullary Nail facilitates minimally invasive insertion, preserving soft tissue and promoting earlier patient mobilization.

Advanced Solution for Distal Femoral Fractures

At OrthoPro, we understand the complexities involved in treating fractures of the distal femur. Our Distal Femur Intramedullary Nail (DFN) system is meticulously designed to address these challenges, offering a robust solution for supracondylar and intercondylar fractures. As a retrograde nailing system, it provides an optimal biomechanical environment for bone healing, particularly in cases where the bone quality is compromised or where soft tissue preservation is paramount.

The Distal Femur Intramedullary Nail is a cornerstone of modern orthopedic trauma surgery. Unlike lateral plating, the intramedullary load-sharing design of our DFN minimizes the risk of implant failure and allows for earlier weight-bearing. This makes it an ideal choice for hospitals and trauma centers looking to improve patient outcomes while managing costs effectively. As a dedicated B2B supplier, OrthoPro ensures that every implant meets rigorous international quality standards.

Key Features and Biomechanical Advantages

Our DFN system incorporates advanced engineering to facilitate surgical ease and fixation stability:

  • Retrograde Insertion: Designed for insertion through the intercondylar notch, which is particularly advantageous for patients with ipsilateral hip implants or multiple trauma.
  • Multi-Planar Locking: The distal end of the nail features multiple locking holes in different planes. This allows for the placement of locking screws that create a fixed-angle construct, essential for stabilizing short distal fragments and intra-articular blocks.
  • Anatomic Design: The nail has a specific radius of curvature to match the average anatomy of the distal femur, reducing the risk of anterior cortex impingement during insertion.
  • Cannulated System: The hollow core allows for guide-wire guided insertion, ensuring precise placement and alignment.
  • Titanium Alloy Construction: Manufactured from Ti-6Al-4V, providing excellent biocompatibility, high fatigue strength, and MRI compatibility.
  • End Cap Options: Various end cap lengths are available to extend the nail length if necessary and to prevent bony ingrowth into the driving end.

Indications for Use

The OrthoPro Distal Femur Intramedullary Nail is indicated for a wide range of femoral injuries:

  • Supracondylar fractures (AO/OTA 33-A).
  • Intra-articular fractures (AO/OTA 33-C).
  • Distal femoral shaft fractures extending to the metaphysis.
  • Pathological fractures.
  • Non-unions and malunions.
  • Periprosthetic fractures proximal to a total knee arthroplasty (TKA).

Technical Specifications

We provide a comprehensive range of sizes to accommodate different patient anatomies. Our inventory is designed to cover the vast majority of clinical cases encountered.

Parameter Specification Details
Material Titanium Alloy (Ti-6Al-4V) / Stainless Steel
Nail Diameter 9mm, 10mm, 11mm, 12mm, 13mm
Nail Length 160mm to 420mm (Standard increments)
Distal Diameter 11mm – 13mm (Expanded for stability)
Locking Screws 5.0mm Interlocking Screws / Condylar Screws
Condylar Nut Optional for enhanced fixation
Bend Anatomic curvature (approx. 1.5m – 2.0m radius)
End Caps 0mm, 5mm, 10mm, 15mm extension options

Surgical Technique Support

The success of the Distal Femur Intramedullary Nail procedure relies on precise instrumentation. OrthoPro provides a complete instrument set designed for efficiency. The radiolucent targeting arm allows for accurate distal locking without obstructing fluoroscopic views. The spiral blade or condylar screws can be inserted using the same targeting guide, simplifying the workflow in the operating room.

Surgeons appreciate the ability to compress the fracture gap using the internal compression mechanism available in our system. This feature is critical for promoting primary bone healing and reducing the gap in non-union cases.

Why Partner with OrthoPro?

For medical device distributors and hospital procurement officers, OrthoPro offers a compelling value proposition:

  1. Quality Assurance: All our implants are manufactured in ISO 13485 certified facilities, ensuring consistency and safety.
  2. Supply Chain Reliability: We maintain a strategic inventory of DFN systems to ensure rapid fulfillment of orders, minimizing downtime for your clients.
  3. Competitive Pricing: Our direct-to-B2B model eliminates unnecessary markups, offering you high-quality trauma implants at competitive wholesale prices.
  4. Global Reach: We have extensive experience shipping to non-Chinese regions, handling logistics to North America, Europe, Latin America, and beyond.

Enhance your orthopedic trauma catalog with a product that surgeons trust. The Distal Femur Intramedullary Nail is a versatile, reliable, and essential tool for modern fracture care.

Request a Quote Today

Are you looking for a reliable supplier of retrograde femoral nails? Contact our sales team to discuss bulk pricing, shipping options, and distributor opportunities.

For inquiries, please visit our Contact Page or send an email directly to info@orthopro.mx. We are ready to support your business.