Have any questions?       +86-13236009512   info@orthopro.mx

Femoral Intramedullary Nail & Reconstruction System – Titanium Interlocking Nail for Femur Fractures

The Femoral Intramedullary Nail is a versatile orthopedic implant designed for the stabilization of femoral shaft and subtrochanteric fractures. Featuring a dual-mode design, this Femoral Reconstruction Nail allows for standard interlocking or reconstruction locking, providing surgeons with flexibility in trauma cases. Manufactured from high-strength titanium alloy, our Femoral Intramedullary Nail system ensures optimal biomechanical fixation and anatomical alignment.

Advanced Femoral Intramedullary Nail System for Trauma Reconstruction

At OrthoPro, we are dedicated to providing world-class orthopedic solutions to global healthcare providers. Our **Femoral Intramedullary Nail** is a comprehensive intramedullary nailing system designed to treat a wide range of femoral fractures. Whether dealing with simple shaft fractures or complex proximal femur injuries, this **Femoral Reconstruction Nail** offers the stability, precision, and ease of use required in modern trauma surgery.

Engineered for excellence, this system serves as a primary choice for orthopedic surgeons seeking a reliable **titanium interlocking nail** that simplifies operative techniques while maximizing patient outcomes. It is an essential addition to the inventory of hospitals and medical distributors specializing in trauma care.

Versatile Dual-Mode Design

One of the standout features of our **Femoral Intramedullary Nail** is its versatility. The proximal section of the nail is designed to accommodate different locking configurations, allowing the surgeon to choose between two modes based on the fracture pattern:

  • Standard Interlocking Mode: Ideal for femoral shaft fractures (Type 32-A/B/C). In this mode, locking screws are placed transversely to control rotation and length.
  • Reconstruction Mode: Specifically designed for subtrochanteric fractures and combined femoral neck/shaft fractures. This mode utilizes lag screws inserted into the femoral head to provide rotational stability and prevent varus collapse.

Key Features and Benefits

Our **Femoral Reconstruction Nail** incorporates advanced design elements to enhance surgical efficiency and fixation strength:

  • Anatomical Geometry: The nail features an optimal anteversion angle and anatomical bow (radius of curvature) to match the natural shape of the femur, facilitating easier insertion and reducing the risk of cortical impingement.
  • Titanium Alloy Construction: Manufactured from medical-grade Titanium Alloy, ensuring excellent biocompatibility, high fatigue strength, and MRI compatibility.
  • Distal Locking Options: The distal end of the nail offers multiple locking holes (static and dynamic) to ensure stability even in distal third fractures.
  • Cannulated Design: The nail is fully cannulated to allow for insertion over a guide wire, compatible with both reamed and unreamed techniques.
  • Tapered Tip: The distal tip is tapered to facilitate insertion and reduce stress concentrations at the tip of the nail.

Indications for Use

The **Femoral Intramedullary Nail** system is indicated for the internal fixation of a variety of femoral fractures, making it a “workhorse” implant for trauma centers. Indications include:

  • Comminuted and segmental fractures of the femoral shaft.
  • Subtrochanteric fractures.
  • Ipsilateral femoral neck and shaft fractures.
  • Pathological fractures due to osteoporosis or tumors.
  • Non-unions and mal-unions of the femur.

Technical Specifications

Our system offers a wide range of sizes to accommodate different patient anatomies. While specific parameters can be customized for large B2B orders, the standard range includes:

  • Nail Diameters: Available in diameters typically ranging from 9mm to 12mm to fit various medullary canal sizes.
  • Nail Lengths: A comprehensive range of lengths (e.g., 320mm to 440mm) to ensure proper span of the fracture zone.
  • Proximal Diameter: Reinforced proximal end (e.g., 13mm) to accommodate sturdy reconstruction screws.
  • Lag Screw Angles: Designed with specific angles (typically 125°, 130°, 135°) to suit different femoral neck anatomies.

Quality Assurance and Supply

As a trusted partner in the orthopedic industry, OrthoPro ensures that every **Femoral Intramedullary Nail** undergoes rigorous quality control. We cater specifically to B2B clients, including distributors and hospital procurement departments, offering competitive pricing and reliable shipping logistics outside of China.

Investing in our **Femoral Reconstruction Nail** means investing in a product that combines biomechanical stability with surgical flexibility, ultimately aimed at restoring patient mobility faster.

Contact Us for a Quote

Are you looking for a reliable supplier of high-quality **orthopedic trauma implants**? Contact our team today to discuss your requirements, request a catalog, or get a customized quote.

Inquire About This Product

For direct inquiries, please email us at: info@orthopro.mx.