{"id":1403,"date":"2026-03-04T13:31:52","date_gmt":"2026-03-04T13:31:52","guid":{"rendered":"https:\/\/orthopro.mx\/?post_type=product&#038;p=1403"},"modified":"2026-03-04T13:31:53","modified_gmt":"2026-03-04T13:31:53","slug":"proximal-radius-locking-plate-3","status":"publish","type":"product","link":"https:\/\/orthopro.mx\/es\/product\/proximal-radius-locking-plate-3\/","title":{"rendered":"Proximal Radius Locking Plate II \u2013 Radial Neck &amp; Head Fracture Fixation System | Orthopedic Trauma Implants"},"content":{"rendered":"<div class=\"product-description-wrapper\">\n<h2>Advanced Solution for Radial Neck and Head Fractures<\/h2>\n<p>Welcome to OrthoPro, a leading provider of high-quality orthopedic solutions for the global B2B market. The <strong>Proximal Radius Locking Plate<\/strong> II is a specialized trauma implant designed to address the unique anatomical challenges of the elbow joint. Fractures of the proximal radius, particularly those affecting the radial neck and head, require precise fixation to restore forearm rotation and elbow stability. Our system provides surgeons with the tools necessary to achieve optimal anatomical reduction and stable fixation.<\/p>\n<p>The OrthoPro <strong>Proximal Radius Locking Plate<\/strong> II features a pre-contoured low-profile design. This is critical in the proximal forearm, where soft tissue coverage is thin and the risk of impingement is high. By adhering closely to the bone surface, our plates reduce the likelihood of tendon irritation and facilitate earlier patient mobilization.<\/p>\n<h3>Design Philosophy and Features<\/h3>\n<p>Our engineering team focuses on biomechanical stability and surgical efficiency. The <strong>Proximal Radius Locking Plate<\/strong> II incorporates several advanced features:<\/p>\n<ul>\n<li><strong>Anatomical Shape:<\/strong> The plate is pre-bent to fit the lateral aspect of the proximal radius. This specific contour targets the \u201csafe zone\u201d\u2014an area of the radial head where implant placement does not impinge on the proximal radioulnar joint during rotation.<\/li>\n<li><strong>Dual Screw Diameter System:<\/strong> The proximal head of the plate accepts 2.4mm locking screws to secure small bone fragments in the radial head. The shaft accepts 2.7mm locking or cortical screws, providing strong anchorage in the radial shaft.<\/li>\n<li><strong>Tecnolog\u00eda de Bloqueo:<\/strong> The angular stability provided by the locking screws creates a load-sharing construct. This is particularly beneficial in osteoporotic bone or comminuted fractures where traditional screw purchase is compromised.<\/li>\n<li><strong>Versatile Hole Configuration:<\/strong> The combi-holes in the shaft allow for compression or locking, giving the surgeon flexibility based on the fracture pattern.<\/li>\n<li><strong>Low Profile:<\/strong> The plate thickness and screw head prominence are minimized to prevent irritation of the overlying supinator muscle and lateral collateral ligament complex.<\/li>\n<\/ul>\n<h3>Indications for Use<\/h3>\n<p>The OrthoPro <strong>Proximal Radius Locking Plate<\/strong> II is indicated for a range of trauma patterns, including:<\/p>\n<ul>\n<li>Fractures of the radial neck.<\/li>\n<li>Fractures of the radial head (Mason Type II and III).<\/li>\n<li>Intra-articular and extra-articular proximal radius fractures.<\/li>\n<li>Reconstruction of non-unions or malunions of the proximal radius.<\/li>\n<li>Multi-fragmentary fractures requiring buttress plating.<\/li>\n<\/ul>\n<h3>Especificaciones t\u00e9cnicas<\/h3>\n<p>Our implants are manufactured under strict quality control to meet international medical standards. Below are the specific parameters for this system:<\/p>\n<table style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; border-color: #dddddd;\" border=\"1\" cellspacing=\"0\" cellpadding=\"10\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th style=\"text-align: left;\">Caracter\u00edstica<\/th>\n<th style=\"text-align: left;\">Especificaci\u00f3n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Material<\/strong><\/td>\n<td>Titanium Alloy (Ti-6Al-4V) or Medical Grade Stainless Steel<\/td>\n<\/tr>\n<tr>\n<td><strong>Tipo de placa<\/strong><\/td>\n<td>Proximal Radius Locking Plate II<\/td>\n<\/tr>\n<tr>\n<td><strong>Proximal Screw Size<\/strong><\/td>\n<td>2.4mm Locking Screws<\/td>\n<\/tr>\n<tr>\n<td><strong>Shaft Screw Size<\/strong><\/td>\n<td>2.7mm Locking Screws \/ 2.7mm Cortical Screws<\/td>\n<\/tr>\n<tr>\n<td><strong>Orientaci\u00f3n<\/strong><\/td>\n<td>Anatomically Left and Right<\/td>\n<\/tr>\n<tr>\n<td><strong>Hole Count<\/strong><\/td>\n<td>Typically available in 2, 3, and 4 hole shaft lengths<\/td>\n<\/tr>\n<tr>\n<td><strong>Acabado superficial<\/strong><\/td>\n<td>Anodized (Type II) for improved fatigue strength and biocompatibility<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Why Choose OrthoPro for Your Inventory?<\/h3>\n<p>At OrthoPro, we understand that medical distributors and hospitals require more than just a product; they need a reliable partner. We specialize in serving the B2B market outside of China, ensuring that our <strong>orthopedic trauma implants<\/strong> meet the rigorous demands of modern surgery.<\/p>\n<p><strong>Fiabilidad de la cadena de suministro:<\/strong> We maintain a robust inventory of <strong>Proximal Radius Locking Plates<\/strong> to ensure rapid fulfillment of orders. Whether you are stocking a trauma center or distributing to a network of hospitals, we guarantee consistent availability.<\/p>\n<p><strong>Garant\u00eda de Calidad:<\/strong> Every plate and screw undergoes stringent inspection. Our Titanium alloy is sourced for its superior strength-to-weight ratio and excellent MRI compatibility, which is essential for post-operative assessment.<\/p>\n<h3>Descripci\u00f3n general de la t\u00e9cnica quir\u00fargica<\/h3>\n<p>The application of the <strong>Proximal Radius Locking Plate<\/strong> II typically involves a lateral approach to the elbow (Kaplan or Kocher). Identifying the \u201csafe zone\u201d is crucial\u2014this is a 90-degree arc on the radial head that does not articulate with the ulna. Our plates are designed to fit precisely within this zone. The ability to use locking screws in a diverging pattern allows for a \u201craft\u201d of support under the articular surface, preventing subsidence of fracture fragments.<\/p>\n<h3>Contact Us for B2B Pricing<\/h3>\n<p>Are you looking to expand your orthopedic product line with high-quality, cost-effective trauma solutions? OrthoPro is here to support your business.<\/p>\n<p>For detailed catalogs, pricing inquiries, or to place a wholesale order, please contact our team today. We provide comprehensive support for distributors and healthcare providers.<\/p>\n<p><strong>Env\u00edenos un correo electr\u00f3nico a:<\/strong> <a href=\"mailto:info@orthopro.mx\">info@orthopro.mx<\/a><\/p>\n<p style=\"text-align: center; margin-top: 30px;\"><a style=\"background-color: #0073aa; color: #ffffff; padding: 15px 30px; text-decoration: none; border-radius: 5px; font-weight: bold; font-size: 16px;\" href=\"https:\/\/orthopro.mx\/es\/contactenos\/\" target=\"_blank\" rel=\"noopener\">Solicite una cotizaci\u00f3n ahora<\/a><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p><span class=\"ng-star-inserted\">The OrthoPro\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Proximal Radius Locking Plate<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0II is expertly engineered for the internal fixation of fractures in the radial neck and head. Featuring an anatomical contour that respects the \u201csafe zone\u201d of the proximal radius, this\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">proximal radius locking plate<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0minimizes soft tissue interference while providing rigid stability. Our\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">proximal radius locking plate<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0system utilizes 2.4mm and 2.7mm screws, offering versatile solutions for complex elbow trauma.<\/span><\/p>","protected":false},"featured_media":1404,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[67],"product_cat":[26],"product_tag":[1286,1014,1015,1285],"class_list":{"0":"post-1403","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-orthopro","7":"product_cat-locking-plate","8":"product_tag-elbow-internal-fixation","9":"product_tag-proximal-radius-locking-plate","10":"product_tag-radial-head-fracture-plate","11":"product_tag-radial-neck-locking-plate","13":"first","14":"instock","15":"shipping-taxable","16":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/orthopro.mx\/es\/wp-json\/wp\/v2\/product\/1403","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/orthopro.mx\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/orthopro.mx\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/orthopro.mx\/es\/wp-json\/wp\/v2\/comments?post=1403"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/orthopro.mx\/es\/wp-json\/wp\/v2\/media\/1404"}],"wp:attachment":[{"href":"https:\/\/orthopro.mx\/es\/wp-json\/wp\/v2\/media?parent=1403"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/orthopro.mx\/es\/wp-json\/wp\/v2\/product_brand?post=1403"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/orthopro.mx\/es\/wp-json\/wp\/v2\/product_cat?post=1403"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/orthopro.mx\/es\/wp-json\/wp\/v2\/product_tag?post=1403"}],"curies":[{"name":"Libro blanco","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}