Have any questions?       +86-13236009512   info@orthopro.mx

Reversed Femoral Nail System | Titanium Proximal Femoral Intramedullary Implant for Trochanteric Fractures

The Reversed Femoral Nail is a specialized intramedullary system engineered for the stable fixation of pertrochanteric, intertrochanteric, and high subtrochanteric fractures. This advanced Reversed Femoral Nail features an anatomic design that ensures optimal fit and rotational stability. Manufactured for trauma surgery excellence, our proximal femoral nail facilitates minimally invasive insertion and promotes early patient mobilization.

Advanced Solution for Proximal Femur Fractures

At OrthoPro, we are dedicated to providing orthopedic surgeons with reliable and efficient solutions for trauma care. The Reversed Femoral Nail system is a state-of-the-art intramedullary implant designed specifically to address the challenges of proximal femoral fractures. With the aging global population, the incidence of hip fractures is rising, making a high-quality, cost-effective proximal femoral nail an essential component of any hospital’s inventory.

Our Reversed Femoral Nail combines biomechanical stability with surgical ease. It is engineered to withstand the high weight-bearing loads transmitted through the hip joint while preventing common complications such as varus collapse and rotation of the femoral head. As a trusted B2B supplier, OrthoPro ensures that every implant meets rigorous international quality standards, delivering peace of mind to distributors and surgeons alike.

Biomechanical Features and Clinical Benefits

The design of the Reversed Femoral Nail focuses on preserving bone biology and ensuring rigid fixation. Key features include:

  • Anatomic Geometry: The nail features a 6° proximal valgus bend (mediolateral angle), which facilitates insertion through the tip of the greater trochanter, minimizing damage to the gluteal muscles and tendons.
  • Anti-Rotation Mechanism: The system utilizes a specialized proximal locking screw or helical blade design (depending on configuration) that increases the contact area with the femoral head bone, providing superior resistance to rotation and cut-out, especially in osteoporotic bone.
  • Distal Locking Options: The nail offers both static and dynamic distal locking holes. Dynamic locking allows for controlled compression at the fracture site during healing, while static locking maintains length and rotation in unstable fractures.
  • Grooved Design: The surface of the nail is often designed to reduce stiffness appropriately, avoiding stress shielding while maintaining the strength required for load-bearing.
  • Optimized Tip: The distal tip is tapered to reduce stress concentration at the end of the nail, lowering the risk of secondary femoral shaft fractures.

Indications for Use

The OrthoPro Reversed Femoral Nail is indicated for a wide spectrum of proximal femoral injuries:

  • Stable and unstable pertrochanteric fractures.
  • Intertrochanteric fractures.
  • High subtrochanteric fractures.
  • Basal neck fractures.
  • Combined femoral neck and shaft fractures (using long nail variations).
  • Pathological fractures due to osteoporosis or metastasis.

Technical Specifications

We offer a comprehensive range of nail sizes and locking options to accommodate various patient anatomies. Our manufacturing utilizes premium Titanium Alloy (Ti-6Al-4V) for excellent biocompatibility and fatigue strength.

Parameter Specification Details
Material Titanium Alloy (Ti-6Al-4V)
Proximal Diameter 16mm – 17mm (Optimized for trochanteric entry)
Distal Diameter 9mm, 10mm, 11mm, 12mm
Nail Length (Short) 170mm, 200mm, 240mm
Nail Length (Long) 300mm to 420mm (20mm increments)
CCD Angle (Caput-Collum-Diaphyseal) 125°, 130° options available
Proximal Screw/Blade Cannulated Compression Screw / Helical Blade
Distal Locking Screws 4.9mm Locking Screws
End Caps 0mm, 5mm, 10mm extensions

Surgical Technique & Instrumentation

The implantation of the Reversed Femoral Nail is supported by a streamlined and radiolucent instrumentation set. The cannulated technique allows for accurate guide-wire placement before reaming and nail insertion. The targeting arm is made of carbon fiber, ensuring it does not obstruct the surgeon’s view under fluoroscopy (C-arm).

The system is designed for a minimally invasive approach, which significantly reduces blood loss, postoperative pain, and recovery time. The proximal locking mechanism incorporates a locking device to prevent the screw from backing out, ensuring long-term stability.

Why Partner with OrthoPro?

In the competitive landscape of medical devices, OrthoPro stands out as a reliable partner for global distributors and hospitals:

  1. Quality Assurance: Our manufacturing facilities are ISO 13485 certified. Every reversed femoral nail undergoes strict quality control inspections.
  2. Inventory & Logistics: We maintain a strategic stock of common sizes to ensure rapid dispatch for urgent trauma requirements. We ship globally to North America, Europe, LATAM, and Asia.
  3. Competitive B2B Pricing: By sourcing directly from OrthoPro, you bypass unnecessary intermediaries, securing high-quality implants at competitive wholesale rates.
  4. Marketing Support: We provide technical datasheets, high-resolution images, and surgical guides to assist your sales team.

Choose the Reversed Femoral Nail from OrthoPro for a solution that balances clinical efficacy with economic value.

Request a Quote Today

Are you looking for a reliable supplier of proximal femoral nails? Contact our sales team to discuss bulk pricing, OEM opportunities, and shipping options.

For inquiries, please visit our Contact Page or send an email directly to info@orthopro.mx. We look forward to supporting your business.