Have any questions?       +86-13236009512   info@orthopro.mx

Scapula Lateral Locking Plate | Anatomic Titanium Implant for Lateral Border Fracture Fixation

The Scapula Lateral Locking Plate is a specialized orthopedic implant engineered for the rigid internal fixation of fractures along the lateral border of the scapula. Featuring a pre-contoured anatomical design, this Scapula Lateral Locking Plate restores the structural integrity of the shoulder girdle while minimizing soft tissue irritation. Our lateral scapula locking plate system supports both locking and cortical screws, providing surgeons with versatile solutions for complex scapular body and glenoid neck fractures.

Premium Scapula Lateral Locking Plate for Advanced Shoulder Reconstruction

At OrthoPro, we are dedicated to supplying high-precision orthopedic solutions to medical distributors and hospitals worldwide. Our Scapula Lateral Locking Plate is a cornerstone of our upper limb trauma portfolio, meticulously designed to address the unique anatomical challenges of the scapula. Fractures of the scapula, particularly those involving the lateral border (the “pillar” of the scapula), require robust fixation to restore shoulder mechanics and ensure proper rotator cuff function.

Traditional plating methods often struggle with the complex 3D geometry of the scapula. The OrthoPro Scapula Lateral Locking Plate solves this by offering an anatomically pre-contoured solution that matches the lateral margin’s curvature. This design minimizes the need for intraoperative plate bending, reduces surgical time, and ensures a low-profile fit that reduces palpability and irritation of the overlying muscle and skin.

The Importance of the Lateral Pillar

Restoring the lateral border is critical in scapular surgery. It serves as the primary strut for the glenoid and the attachment site for key stabilizer muscles. Our Scapula Lateral Locking Plate is engineered to bridge comminuted fractures in this region, providing a stable platform for early rehabilitation. By securing the lateral column, surgeons can effectively neutralize forces acting on the glenoid fossa, preventing malunion and long-term dysfunction.

Key Features and Design Benefits

Our fixation system incorporates advanced locking screw technology to ensure rigid stability, even in osteopenic bone. Key features include:

  • Anatomical Contour: The plate is specifically shaped to follow the twist and curve of the lateral scapular border, allowing for immediate application with minimal modification.
  • Versatile Hole Configuration: The shaft features combination holes (Combi-holes) that accept both locking screws for angular stability and cortical screws for dynamic compression. This flexibility allows the surgeon to compress fracture lines or bridge comminuted zones as required.
  • Low-Profile Architecture: With tapered edges and a reduced thickness, the plate preserves the blood supply to the periosteum and minimizes soft tissue impingement.
  • Distal & Proximal Fixation: The plate design includes optimized screw clusters at the glenoid neck and the inferior angle to maximize screw purchase in the densest bone available.
  • Material Excellence: Available in high-grade Titanium Alloy (Ti-6Al-4V) or Medical Stainless Steel, ensuring biocompatibility and superior fatigue strength.

Technical Specifications

Manufactured to meet rigorous international quality standards (ISO/CE compliant processes), the OrthoPro system ensures compatibility and performance. Below are the technical parameters based on standard configurations:

Material Titanium Alloy (Ti-6Al-4V) / Stainless Steel (316L)
Plate Orientation Left / Right Specific
Hole Configurations Available in 4, 5, 6, 7, 8, 9, 10 holes
Screw Compatibility 2.7mm / 3.5mm Locking & Cortical Screws
Plate Thickness Approx. 2.5mm – 3.0mm (Tapered)
Fixation Type Locking (Fixed-Angle) and Compression
Surface Treatment Anodized (Titanium) / Electropolished (SS)

Surgical Indications

The OrthoPro Scapula Lateral Locking Plate is indicated for a variety of scapular trauma patterns:

  • Extra-articular fractures of the scapular body involving the lateral border.
  • Fractures of the glenoid neck (extra-articular).
  • Comminuted scapula fractures requiring open reduction and internal fixation (ORIF).
  • Non-unions and malunions of the scapular lateral margin.
  • Floating shoulder injuries (in combination with clavicle fixation).

Why Partner with OrthoPro?

Choosing OrthoPro as your orthopedic supply partner means choosing reliability and value. We understand the specific needs of B2B clients in the medical sector:

  • Quality Assurance: All implants undergo strict mechanical testing and quality control inspections.
  • Competitive Wholesale Pricing: We offer factory-direct pricing structures to help distributors maximize their margins.
  • Global Logistics: Efficient shipping solutions ensure your hospital or warehouse stock is replenished on time.
  • Full Regulatory Support: We assist with the necessary documentation for product registration in your local market.

Enhance your trauma product catalog with our high-performance Scapula Lateral Locking Plate. For detailed product brochures, price lists, and sample requests, please contact our sales team.

Visit our Contact Us page or email us directly at info@orthopro.mx to request a quote today.